Counter Flow Frp Square Cooling Tower
Counter Flow Frp Square Cooling Tower

Counter Flow Frp Square Cooling Tower

MOQ : 1 Unit

Counter Flow Frp Square Cooling Tower Specification

  • Material
  • FRP (Fibre Reinforced Plastic) Casing, GI Hardware, PVC Fill Pack
  • Refrigerating Capacity
  • Based on design - typically from 10 TR to 1000+ TR
  • Application
  • Industrial water cooling, HVAC, Power Plants, Chemical Industry
  • Motor
  • Totally Enclosed Fan Cooled (TEFC), IP55, 3-phase
  • Air Flow
  • High Volume Axial Fan Driven
  • Condition
  • New
  • Type
  • Counter Flow Square Cooling Tower
  • Dimension (L*W*H)
  • As per capacity (Custom design possible)
  • Power Supply
  • 415V 10%, 50Hz, 3 Phase
  • Voltage
  • 415 V
  • Cooling Type
  • Counter Flow, Induced Draft
  • Nozzle Material
  • ABS Plastic/PP
  • Cooling Coil Material
  • Not Applicable / PVC Fills (No coil design)
  • Water Flowing Rate
  • Customizable as per capacity (typically 10-200 m3/hr)
  • Water Pump Motor
  • Compatible as per water flow & tower size
  • Noise Control
  • Low Noise Fan Technology, Optional Sound Attenuators
  • Service Life
  • >10 years with proper maintenance
  • Corrosion Resistance
  • High due to FRP Construction
  • Fill Media
  • Corrugated PVC Sheets, Honeycomb structure
  • Fan Type
  • Dynamically Balanced Aluminum Fan
  • Packaging
  • Assembled or Knock-Down as per request
  • Installation Location
  • Indoor/Outdoor
  • Heat Dissipation
  • Optimal by high surface area fills
  • Maintenance Access
  • Provision for Manhole & Easy Service Access
  • Operating Temperature
  • Up to 60C water inlet
  • Outlet Connection
  • Flanged / Threaded as per specification
  • Inlet Connection
  • Flanged / Threaded as per specification
  • Drift Eliminator
  • High Efficiency PVC / PP Material
  • Structural Frame
  • Hot Dip Galvanized Steel / FRP Support
  • Color
  • Blue (standard, customizable)
 

Counter Flow Frp Square Cooling Tower Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 50 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Counter Flow Frp Square Cooling Tower



Discover the ultimate in industrial cooling with our Counter Flow FRP Square Cooling Tower-a hot deal for businesses seeking a superior, long-lasting solution. This cooling tower features a dynamically balanced aluminum fan for lofty air flow and an ephemeral noise profile thanks to low noise technology. Its customizable structure stands strong on hot dip galvanized steel or FRP supports, and offers exceptional corrosion resistance. With high-efficiency drift eliminators and honeycomb fills, optimal heat dissipation is assured. Delivered assembled or knock-down, the color and capacity are customizable for every application.

Unique Features, Applications, and General Uses

This Counter Flow FRP Square Cooling Tower is equipped with robust FRP casing, GI hardware, and high-efficiency PVC fill packs. Designed for both indoor and outdoor installations, it serves in various industries-HVAC, power plants, and chemical processing facilities-providing efficient heat rejection for water cooling. The customizable water flow, superior heat dissipation, and accessible manholes make it ideal for industrial water recycling, process cooling, and energy management, ensuring a reliable solution for diverse applications.


Exports, Supply Capabilities, and Delivery Details

Our cooling towers enjoy robust demand in main export markets across Asia, Africa, and the Middle East. With high supply ability, we meet sizable orders and offer sample units to support project evaluation. List price includes standard packaging-assembled or knock-down-as per client needs. Shipments are managed efficiently for swift delivery, with comprehensive after-sales support. Tailored shipments, flexible supply options, and prompt delivery ensure smooth onboarding for industrial, HVAC, and OEM clients alike.


FAQ's of Counter Flow Frp Square Cooling Tower:


Q: How is the Counter Flow FRP Square Cooling Tower customized for different capacities?

A: The cooling tower can be designed with tailored water flow rates, dimensions, and specifications, ranging from 10 m3/hr up to 200 m3/hr or more, ensuring it meets your exact process requirements.

Q: What benefits does the dynamically balanced aluminum fan offer?

A: This fan ensures high air flow with low vibration and minimal noise, resulting in superior heat rejection and a quiet operation environment.

Q: Where can the Counter Flow FRP Square Cooling Tower be installed?

A: It is suitable for both indoor and outdoor locations, thanks to its highly corrosion-resistant FRP and galvanized steel structure.

Q: What kind of maintenance access is provided for this cooling tower?

A: Maintenance is streamlined with integrated manhole access and easy service panels, facilitating routine inspection and servicing without extensive downtime.

Q: What industries commonly use this cooling tower?

A: It is extensively used in industrial water cooling, HVAC, chemical processing, refrigeration, and power plants for efficient heat rejection and process stabilization.

Q: How does the tower ensure optimal heat dissipation?

A: The use of high surface area corrugated PVC sheets and honeycomb structure fill media maximizes contact surface, greatly improving the cooling effect and energy efficiency.

More Products in Cooling Tower Category

frp cooling tower in punjab

frp cooling tower in punjab

Minimum Order Quantity : 1 Unit

Application : Industrial Cooling

Type : Induced Draft Cooling Tower

Material : Other , FRP (Fibre Reinforced Plastic)

Water Flowing Rate : 75 m/hr

Condition : New

Industrial MS Cooling Tower

Industrial MS Cooling Tower

Minimum Order Quantity : 1 Unit

Application : Industrial Process Cooling: Power Plants, HVAC, Factories, Chemical Plants

Type : Induced Draft Rectangular MS Cooling Tower

Material : Other , Mild Steel (MS) Structure with Corrosion Resistant Coating

Water Flowing Rate : Customized as per requirement (e.g. 75 m3/hr to 1000 m3/hr)

Condition : New

Square type Cooling Tower

Square type Cooling Tower

Minimum Order Quantity : 1 Unit

Application : Chemical Plant

Type : Square Type Cooling Tower

Material : FRP

Water Flowing Rate : 6m3/hr

Condition : New

Natural Draft Cooling Tower

Natural Draft Cooling Tower

Minimum Order Quantity : 1 Unit

Application : Food Industry

Type : RCC Natural Draft Tower

Material : Other , RCC

Water Flowing Rate : 50 m/hr

Condition : New



Back to top