Working Hours

Mon - Sat 10:00 - 7:00
Counter Flow FRP Cooling Tower, Square, Induced Draft
Counter Flow FRP Cooling Tower, Square, Induced Draft

Counter Flow FRP Cooling Tower, Square, Induced Draft

MOQ : 1 Unit

Counter Flow FRP Cooling Tower, Square, Induced Draft Specification

  • Refrigerating Capacity
  • 200 TR
  • Material
  • FRP (Fibre Reinforced Plastic)
  • Motor
  • Electric, fan motor
  • Air Flow
  • Side-mounted induced draft
  • Application
  • HVAC, Industrial use
  • Condition
  • New
  • Type
  • Square, Induced Draft Cooling Tower
  • Dimension (L*W*H)
  • Approx. Large, multi-cell unit
  • Power Supply
  • 3 phase, industrial power
  • Voltage
  • 415V (typical industrial)
  • Cooling Type
  • Forced air, wet cooling
  • Nozzle Material
  • Corrosion resistant plastic
  • Cooling Coil Material
  • Not applicable (open tower)
  • Water Flowing Rate
  • 120 m3/hr
  • Water Pump Motor
  • Not included
  • Noise Control
  • Low noise fan design
  • Compressor
  • Not included
  • Frame
  • Steel reinforced base
  • Casing Color
  • Sky blue
  • Inspection Windows
  • Provided
  • Mounting
  • On-site installation
  • Tower Height
  • Approx. 3.5-4 meters
  • Fan Placement
  • Top mounted
  • Service Access
  • Front and rear
  • Structure
  • Multi-cell square
  • Number of Cells
  • Two
  • Louvers
  • Slatted side panels
  • Drift Eliminators
  • High efficiency
 

Counter Flow FRP Cooling Tower, Square, Induced Draft Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 20 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Counter Flow FRP Cooling Tower, Square, Induced Draft About



Grab this acclaimed Counter Flow FRP Cooling Tower, boasting a top-tier multi-cell square design and valiant sky blue casing. Structured for invincible durability, its steel-reinforced base and slatted louvers optimize performance while the high-efficiency drift eliminators reduce water loss remarkably. With dual inspection windows, front and rear access, and low-noise induced draft technology, it stands as the valorous choice for industrial and HVAC applications. Suitable for a commanding 200 TR refrigerating capacity and a robust 120 m3/hr water rate, this premium unit is ready for on-site installation across India.

Top Features & Competitive Advantages

The Counter Flow FRP Cooling Tower outshines with its steel-reinforced, multi-cell square structure ensuring unparalleled strength and longevity. Reduced maintenance needs and high-torque, low-noise fan enhance long-term reliability. Built-in inspection windows, high-efficiency drift eliminators, and easy-access louvers contribute to swift serviceability. Its valorous sky blue finish and innovative side-mounted air flow mark it as an invincible solution for industrial cooling demands, setting new standards for safety, efficiency, and convenience in its segment.


Supply Chain & Sample Policy Information

Packing & Dispatch of the Counter Flow FRP Cooling Tower takes place following the confirmed Purchase Order and is handled with utmost precision for secured delivery. We ensure swift dispatching to meet client schedules nationwide, catering to the main domestic market across India. Sample requests are assessed as per our established sample policy to guarantee mutual clarity. Reliable supply ability ensures consistent availability for regular or large-scale industrial requirements throughout the year.


FAQ's of Counter Flow FRP Cooling Tower, Square, Induced Draft:


Q: How does the Counter Flow FRP Cooling Tower operate in industrial and HVAC applications?

A: The tower utilizes induced draft technology with a top-mounted fan and side air intake to efficiently circulate air and optimize cooling in industrial processes and large HVAC systems.

Q: What are the advantages of the multi-cell square design?

A: The multi-cell square structure offers enhanced robustness, greater cooling efficiency, and facilitates easier maintenance by providing front and rear service access along with dual inspection windows.

Q: Where can this cooling tower be installed?

A: It is designed for on-site installation in a variety of industrial or HVAC environments throughout India, ensuring flexibility in large commercial and factory settings.

Q: What is the process for ordering and receiving this cooling tower?

A: Once a Purchase Order is confirmed, the unit is packed, dispatched, and delivered as per the agreed timeline, adhering to rigorous shipping and quality standards.

Q: What are the primary benefits of having high-efficiency drift eliminators and low-noise fans?

A: High-efficiency drift eliminators minimize water loss, while low-noise fans ensure quiet operation, making the tower environmentally friendly and suitable for noise-sensitive installations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Frp Cooling Tower Category

Industrial Frp Cooling Tower

Industrial Frp Cooling Tower

Minimum Order Quantity : 1 Unit

Nozzle Material : PVC / ABS

Voltage : 415V

Cooling Type : Water Cooled

Application : Industrial Cooling

Air Flow : Axial Flow

Induced Draft Type FRP Square Cooling Tower

Induced Draft Type FRP Square Cooling Tower

Minimum Order Quantity : 1 Unit

Nozzle Material : ABS/Aluminum/Brass

Voltage : 380V/415V/460V as per application requirement

Cooling Type : Induced Draft, Cross Flow/Counter Flow

Application : HVAC, process water cooling, plastic industry, chemical & pharmaceutical industries, foundries

Air Flow : Highefficiency axial flow fan provides uniform air distribution

400 Tr Water Cooling Tower

400 Tr Water Cooling Tower

Minimum Order Quantity : 1 Unit

Nozzle Material : Plastic / PVC

Voltage : 415 V

Cooling Type : Water Cooled

Application : Process Cooling

Air Flow : High Volume Induced Draft

Industrial Frp Cooling Tower

Industrial Frp Cooling Tower

Minimum Order Quantity : 1 Unit

Nozzle Material : Highgrade plastic or SS (typical)

Voltage : 415 V (typical industrial standard)

Cooling Type : Water cooling

Application : Industrial process cooling

Air Flow : Axial flow system



Back to top